New Thomas Instock Catalog
Hoods and Enclosures
Standard Bench Fume Hoods - Combination Sash Standard chemical fume hoods are innovative and purpose driven products for the research and healthcare industries. These fume hoods are the result of extensive testing and R&D, producing the safest and most adaptable hoods. They provide a clean, bright working environment through this functional design. The expansive interior is enhanced by a 43” tall sight line with a 17” high glass observation panel.
Features: • Combination vertical rising / Horizontal Sliding Sash • Fume Hood is available prewired • 24” (61 cm) or 30" (76 cm) deep clear interior • 28” (71.1 cm) clear sash opening • Standard 43” (110.5 cm) tall full view sash area
Technical Data: These hoods are UL1805 listed and are tested in accordance to ASHRAE-110. All hoods are pre-wired to a junction box on the roof of the hood with two 120 volt AC 20 amp GFCI receptacles on the side posts, LED light, 20 amp light switch and a duplex for an alarm on the roof. Each front post and interior end liner is punched and capped for up to five (5) remote control service fittings. The left hand post is punched and covered for a second electrical fixture at the top which may be used for a fan switch or other electrical device. The right post is punched and covered for an alarm. Service fittings, fan switch, work top, cup sink, alarm, and base units must be ordered separately. Seismic restraints are available upon request. • Easy conversion from CAV to VAV use • Chemically resistant white Polyglass liner • Slotted rear baffle for even plenum balance • Chain and sprocket sash mechanism for ease in operation • Stainless steel round duct collar(s) • Tempered glass sash with full-length formed steel handle for a neat, clean appearance and streamline air passage • Fume hoods that are not stocked have a lead time of 8-10 weeks
100 FPM @ 28” Vertical Sash Opening
100 FPM @ 18” Vertical Sash Opening
100 FPM @ 50% Horizontal Opening
Static Pressure Loss
Static Pressure Loss
Static Pressure Loss
Clear Interior Depth
Duct Size
Cat. No.
Hood Width
TS F-101-48G5 4’ (121.9 cm) 24” (61 cm) 1:10” 739 CFM 0.29”
475 CFM 0.12”
415 CFM 0.09"
TS F-101-48G5D30 4’ (121.9 cm) 30” (76 cm) 1:10” 739 CFM 0.29”
475 CFM 0.12”
415 CFM 0.09"
TS F-101-60G5 5’ (152.4 cm) 24” (61 cm) 1:12” 972 CFM 0.27”
625 CFM 0.11”
549 CFM 0.09"
TS F-101-60G5D30 5’ (152.4 cm) 30” (76 cm) 1:12” 972 CFM 0.27”
625 CFM 0.11”
549 CFM 0.09"
TS F-101-72G5
6’ (182.9 cm) 24” (61 cm) 1:12” 1206 CFM 0.42”
775 CFM 0.17”
692 CFM 0.14"
TS F-101-72G5D30 6’ (182.9 cm) 30” (76 cm) 1:12” 1206 CFM 0.42”
775 CFM 0.17”
692 CFM 0.14"
TS F-101-96G5 8’ (243.8 cm) 24” (61 cm) 2:10” 1672 CFM 0.37”
1075 CFM 0.15”
968 CFM 0.12"
TS F-101-96G5D30 8’ (243.8 cm) 30” (76 cm) 2:10” 1672 CFM 0.37”
1075 CFM 0.15”
968 CFM 0.12"
www.thomassci.com
92
Made with FlippingBook - Online magazine maker