Government Scientific Source Lab Furnishings

Fume Hood Accessories

• These WaterSaver brand remote control fi ttings consist of a brass angle valve with a replaceable seat, an epoxy coated brass nylon color-coded panel fl ange with angle serrated hose connector, a remote control rod assembly with a polished chrome Fittings for Fume Hood

• Shipped loose and installed in fi eld. External Vacuum Breaker

fl ange and a tank nipple, locknut and washer. • Fittings may be used on either side of hood. • Shipped loose and installed in fi eld.

Fitting Type Air (Orange)

Part Number

Fitting Type

Part Number

External Vacuum Breaker

GSL3185N-LR-A GSL3185N-LR-G GSL3185N-LR-N GSL3185N-LR-V

GSL112WSA

Gas (Dark Blue) Nitrogen (Brown) Vacuum (Yellow)

• These WaterSaver brand remote control fi ttings consist of a brass angle valve with a replaceable seat, and epoxy coated brass nylon color-coded panel fl ange with a gooseneck without a vacuum breaker, a remote control rod assembly with a polished chrome fl ange and a tank nipple, locknut and washer. • Shipped loose and installed in fi eld. Cold Water Fitting for Fume Hood

• These WaterSaver brand remote control fi ttings consist of a brass angle valve with a replaceable seat, and epoxy coated brass nylon color-coded panel fl ange with a gooseneck with a vacuum breaker, a remote control rod assembly with a polished chrome fl ange and a tank nipple, locknut and washer. • Shipped loose and installed in fi eld. Cold Water Fitting for Fume Hood

Fitting Type

Part Number

Fitting Type

Part Number

Cold Water with Vacuum Breaker

Cold Water without Vacuum Breaker

GSL3185W-9RSVB

GSL3185W-9RS

Fume Hood Alarm

Fan Blower Switch

• Each INSTOCK ® fume hood is pre-punched for the fast and easy installation of this alarm. • The monitor provides a digital readout of fume hood face velocity and sounds an alarm when the air fl ow falls below safe levels.

• Manual fan motor starter switch, toggle style, single pole, with red pilot light, stainless steel cover plate, and 1 thermal unit. Fixtures shipped loose for installation at the job site by mechanical trades.

• Consisting of a thermostat sensor (mounted through the side wall of the fume hood) and a monitor (mounted on the fascia), the unit gives both a visual and audible alarm. • The monitor also contains test/reset button allowing the user to verify alarm readiness. • This monitor is shipped loose for fi eld installation.

Product

Part Number

For use with a 1 HP fan For use with a 2 HP fan

GS2510FS1P GS2510FS2P

Product

Part Number

Fume Hood Alarm

GSAFA4000

www.govsci.com

44