Fume Hoods
Standard Walk-In Fume Hood Technical Data: • Our hoods are UL1805 listed and are tested in accordance to ASHRAE-110 • All hoods are pre-wired to a junction box on the roof of the hood with two 120 volt AC 20 amp GFCI receptacles on the side posts, T8-fluorescent light ficture with bulb, 20 amp light switch and a duplex for an alarm on the roof • Each fron tpost and interior end liner is punched and capped for up to five (5) remote control service fittings. • The left hand post is punched for a second electrical fixture at the top which may be used for a fan switch or other electrical device. The right post is punched and covered for an alarm. • Serice fittings, fan switch , work floor, cup sink, alarm, and base units must be ordered separately. •
Seismic retraints are available upon request. Walk-In Fume Roof Detail - Standard Depth
24”
48”
24”
Center Line of Duct 10 1/4”
Center Line
Center Line of Duct 10 1/4”
Alarm Outlet Pre-wired Junction Box
Pre-wired Junction Box
35”
35”
T-8 Light
T-8 Lights
48”, 60”, 72”
96”
Walk-In Fume Roof Detail - Standard Depth
24”
48”
24”
Center Line Center Line of Duct 10 1/4”
Center Line of Duct 10 1/4”
Pre-wired Junction Box
41”
41”
T-8 Lights
T-8 Light
48”, 60”, 72”
96”
Hood and Duct Size Chart Hood Size
Duct Size
48" 60" 72" 96"
1:10" 1:12" 1:12" 2:10"